2020-11-12 |
Other |
floor machine squeegee blade |
please reference email. thank you. |
|
|
Complete |
|
2020-11-11 |
|
|
The eclair pump has a broken spring. |
|
|
repaired |
|
2020-11-11 |
|
|
This eclair pump has a broken off bottom piece, that's wedged in the bottom of the filler. |
|
|
repaired |
|
2020-11-11 |
Other |
Backers for Curbside Pickup Signs |
We have laminated signs we need to attach to the posts at each of the parking sports. We'd like to have a sturdy backer on them to prevent them from being blown away/destroyed by the wind. Mike showed me some metal sheeting that we have from another project. Could we attach the metal to the posts (bolts?)and then I can get the signs velcroed to the to them. |
|
|
Complete |
|
2020-11-10 |
Other |
Squeegee blade on floor machine |
One of the two new blades that were put on keeps sliding down, is there any way to make it stay where we want it and not ruin it? |
|
|
replaced |
|
2020-11-09 |
Walk-In |
|
Vacuum Water from under compressors to prevent water laking into delivery room. |
|
|
ok |
|
2020-11-06 |
|
|
The torch nozzle is loose and needs tightening. |
|
|
tightened head |
|
2020-11-05 |
Other |
Tighten bolts (?) that hold glass to the metal on 9 door deck oven windows |
We were cleaning the deck oven windows, and some of the bolts are much loosen then usual, please take a look at them and re-tighten. thanks |
|
|
tightened |
|
2020-11-04 |
Other |
Rack Washing Machine wash tank not filling and burner coming on right away |
Sending email, trying to fill machine, wash tank very little water and burner comes on and heats it up. Not sure what is wrong. |
|
|
Complete |
|
2020-11-04 |
Other |
Need two tanks of propane please for the torch |
|
|
|
put tank on desk |
|
2020-11-04 |
Other |
|
Hey Guys, we are down to one oven broom, I broke one where the handle joins the head, it is currently behind the MIWE oven
Thanks man!!!! |
|
|
repaired |
|
2020-11-03 |
Other |
Paper towel despenser |
Paper towel dispenser won’t stay shut in mix area |
|
|
repaired |
|
2020-11-03 |
Other |
Make Space for the second FlowWrapper |
We need to move a reachin or reachin freezer out of that back area to make more room for the packagers to make the second flow wrapper more effective. |
|
|
unable to move into Frank and Amy's office |
|
2020-11-03 |
Oven |
|
9-door oven steam on the bottom deck has been lacking for the past three days, most noticeable on the third door to the right of that bottom deck. |
|
|
steaming ok this morning |
|
2020-11-03 |
Oven |
|
Steam in the third deck(from the bottom) of the 12door oven has had poor steam of late (last three days) |
|
|
steam was good all morning |
|
2020-11-02 |
Other |
Small wheel underneath the floor machine needs to be replaced again |
It has a hole in it, the same little wheel. Need it replaced ASAP, or it gets worse and we will not be able to use the machine |
|
|
Complete |
|
2020-11-02 |
Walk-In |
|
Vacuum Water from under compressors to prevent water laking into delivery room. |
|
|
vacuumed water |
|
2020-11-02 |
Other |
Floor machine calbe/squeegee |
Since the cable was replaced the squeegee itself is tilting greatly to the right when looking it. still usable but figured best do a work order |
|
|
squeegee support bent iit back |
|
2020-11-01 |
Other |
speed rack |
We have a speed rack with a broken wheel. It is currently located in Hawkins. |
|
|
repaired |
|
2020-11-01 |
Other |
cable broke that was replaced to hold floor squeegee |
the cable broke please replace, not sure if it needed to be stronger as a guess or what works best |
|
|
Complete |
|
2020-11-01 |
Other |
|
Check battery cell levels and flush out cleaner dilution valve |
|
|
cleaned out and filled battery |
|
2020-11-01 |
Other |
Door |
Door knob came off while trying to come in to bakehouse |
|
|
Complete |
|
2020-10-31 |
|
|
Lower propeller lopsided causing it to hit against the drawer bar |
|
|
Complete |
|
2020-10-31 |
|
|
The warehouse door is locking, but something is going on with the locking mechanism. The door locks, but if you pull on it with more force it will come open at times. |
|
|
Complete |
|
2020-10-31 |
|
|
The warehouse door is locking, but something is going on with the locking mechanism. The door locks, but if you pull on it with more force it will come open at times. |
|
|
Duplicate |
|
2020-10-31 |
|
|
The warehouse door is locking, but something is going on with the locking mechanism. The door locks, but if you pull on it with more force it will come open at times. |
|
|
Duplicate |
|
2020-10-28 |
Electrical |
|
Electrical strip by scaling rack and outlet by wood table in scaling stopped working while we were using the egg machines. |
|
|
overloaded circuit reset breaker |
|
2020-10-28 |
|
|
Egg crackers #1 and #3 stopped spinning and we were unable to use them.
Egg cracker #2 is very bumpy and makes the cap jump when using. |
|
|
repaired both |
|
2020-10-28 |
Other |
Rack wash machine |
Doesn't turn on |
|
|
Lock mechanism was hit by someone sliding racks by it. Use on/off switch for now |
|
2020-10-28 |
Other |
dock plate unusable due to gap, need temporary filler |
The concrete loading dock is fractured and sinking, making it unusable since delivery drivers are dumping our ingredients onto the ground. Tom and I discussed a temporary gap filler made of a pressure-treated plywood strip to make the dock functional while a long term solution is sought. |
|
|
filled in with sand mix 24 hours to cure |
|
2020-10-27 |
Other |
egg cracker 3 |
number 3 stopped working |
|
|
dup. |
|
2020-10-27 |
Other |
Hot water in building |
Hot water in building gets cold around 9-10pm. usually takes about 1 hour to kick back in. Has been happening every night for last few days. |
|
|
see Notes |
|
2020-10-27 |
Other |
rack washing machine will not turn on |
i cleaned it and turned it on and its like there is no power. the one On level looks bent and hard to flip postion tho. |
|
|
doplicate |
|
2020-10-27 |
Other |
rack washing machine will not turn on |
i cleaned it and turned it on and its like there is no power. the one On level looks bent and hard to flip postion tho. |
|
|
duplicate |
|
2020-10-26 |
Walk-In |
|
Vacuum Water from under compressors to prevent water laking into delivery room. |
|
|
vacuumed water |
|
2020-10-26 |
|
|
Drain condensation from air compressor tanks of both stationary air compressors |
|
|
drained tanks |
|
2020-10-25 |
Other |
Handtrruck/dollie |
Most of the handtrucks/dollies need tge bolts tightend |
|
|
repaired 4 handtrucks |
|
2020-10-23 |
Other |
Drinking fountain in Pastry overshoots and lands on the floor |
Please adjust lower some, thank you |
|
|
Duplicate |
|
2020-10-23 |
Other |
Floor metal to our room in the entranceway came off |
Please replace |
|
|
leave off |
|
2020-10-22 |
|
|
Egg cracker number 2's on/ off switch fell off. |
|
|
Complete |
|
2020-10-22 |
Other |
needs a wheel |
Set of bucket wheels is missing on wheel. |
|
|
replaced |
|
2020-10-22 |
HVAC |
|
Check filters and replace when necessary. Check P traps for condensation and drain as necessary. Check condensor coils. WEEKLY DURING SPRING SUMMER, MONTHLY AFTER FIRST FREEZE |
|
|
Complete |
|
2020-10-22 |
Other |
mixer bowl wheels |
the wheels for one of the bowls is hard to move. I red tagged the wheels. Bowl is currently sitting on the wheels. |
|
|
Complete |
|
2020-10-21 |
Other |
Pastry speed rack missing bolt on bottom rung. |
Pastry speed rack missing bolt on bottom rung, red tagged & in the Hawkin's space by maintenance room. |
|
|
dup |
|
2020-10-21 |
Other |
Pastry speed rack missing bolt on bottom rung. |
Pastry speed rack missing bolt on bottom rung, red tagged & in the Hawkin's space by maintenance room. |
|
|
repaired |
|
2020-10-21 |
Other |
Paint customer 'foot prints' on the sidewalk |
There is a stencil in my office for 'foot prints'. We'd like orange paint (it could be matching the BAKE! space if there's leftover). We'd like at least 10 pairs and we'd like them spaced at least 6 ft apart. Please locate them with. John and Crystal. Thanks |
|
|
painted |
|
2020-10-21 |
Other |
Reattach wheel to set of bowl wheels |
Set of wheels for mixing bowl had wheel come off. All pieces in Production Manager's office by poppyseed grinder. |
|
|
loctite on threads |
|
2020-10-20 |
Other |
Freezer Truck #2 Location |
Truck #2 needs to be moved to make enough room for a delivery truck to back in. |
|
|
moved truck |
|
2020-10-20 |
Oven |
|
MIWE OVEN has been having steam issues of late most recently the bottom deck on Tues/20th. This has been an ongoing issue that sometimes goes away but today it was present in a deck of 8-grain today. The other decks seem fine but tomorrow/21st is a super small day and would be a good time to take a look if possible thanks guys!!!!! |
|
|
tightened collar |
|
2020-10-20 |
|
|
Digital Heat sealer is not turning on, not sure the problem. |
|
|
fixed short |