2022-10-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
LVO and Rack Washer Dellimed |
|
2022-10-11 |
|
|
Delime with 1 gallon Eco Lyme every 3 weeks and wash down sidewall |
|
|
Complete |
|
2022-09-30 |
|
|
The top round dial (the one that reads the pressure) on the LVO has a broken arm (the part that points to the number). Pretty sure we need this fixed or else we cant read the pressure correctly |
|
|
ordered |
|
2022-09-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
Complete |
|
2022-09-11 |
|
|
Delime with 1 gallon Eco Lyme every 3 weeks and wash down sidewall |
|
|
all caught up this week |
|
2022-09-06 |
|
|
The LVO rinse gauge needle is broken. |
|
|
The rinse guage only works when the rinse cycle is on |
|
2022-08-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
Complete |
|
2022-08-15 |
|
|
LVO rinse temp is not registering. The tank itself is registering, but the rinse temp during rinse cycle is not. |
|
|
checked temp. this am. OK |
|
2022-08-11 |
|
|
Delime with 1 gallon Eco Lyme every 3 weeks and wash down sidewall |
|
|
LVO, Rack Washer and CMA have been delymed |
|
2022-07-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
not needed till next week |
|
2022-07-23 |
|
|
LVO won't run cycle |
|
|
Could not Verify |
|
2022-07-12 |
|
|
LVO isn't reaching minimum required wash temp. |
|
|
150 degrees this morning |
|
2022-06-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
delimed |
|
2022-06-13 |
Other |
delime, change water if needed |
Check over all of the above dishwashers, delime if needed and check to see if water needs to be changed in Rack Washer |
|
|
delimed all but LVO will do 6/14 |
|
2022-06-12 |
|
|
LVO still smells like it might be burning something off in exhaust. |
|
|
Complete |
|
2022-06-10 |
|
|
Wash temp. is low. |
|
|
it is running ok this morning, I will monitor thru the day |
|
2022-05-27 |
|
|
Delime if needed and check water quality in Rack washer. |
|
|
delimed |
|
2022-05-23 |
|
|
LVO is struggling to meet it's minimum rinse temp. Also one of the rinse read dials isn't completely reading the first number. |
|
|
replaced guage |
|
2022-05-13 |
Other |
delime, change water if needed |
Check over all of the above dishwashers, delime if needed and check to see if water needs to be changed in Rack Washer |
|
|
Delimed all |
|
2022-03-08 |
|
|
There's a small slit in the LVO sprayer hose. The slit is up near the sprayer attachment. The hole needs patching, it's causing water to leak. |
|
|
repaired |
|
2022-03-04 |
|
|
Fan in LVO doesn't seem to be working |
|
|
Complete |
|
2022-02-16 |
|
|
nozzle on hose attached to lvo is loose. |
|
|
could not find any issues |
|
2021-12-30 |
Plumbing |
|
The back bottom left hub only has three screws, it is missing a bunch. |
|
|
replaced hub |
|
2021-12-23 |
|
|
LVO struggled with getting up to minimum wash and rinse temps tonight. |
|
|
Complete |
|
2021-11-08 |
|
|
The rinse pressure gauge needle is broken (tip fell off completely) |
|
|
installed new guage |
|
2021-11-03 |
|
|
while hose in back of LVO is spraying small amount of water |
|
|
repaired |
|
2021-10-20 |
|
|
LVO wash temp. running low. |
|
|
Please read work orders |
|
2021-10-18 |
Other |
|
Wash temp was low all night. |
|
|
Temp. change causes the firing of the burner also to change, I know I have showed everyone how to refire the burner. If you do not remember please ask. |
|
2021-10-14 |
|
|
Lot of condensation coming off the large pipe that lives on top of the LVO. |
|
|
the fan is operational and there will be some condensation around the pipe |
|
2021-09-25 |
|
|
Is leaking water around it's back near the pump and is making a rumbling noise. |
|
|
replaced motor |
|
2021-09-13 |
|
|
soap dispenser for lvo is plugged |
|
|
replaced line |
|
2021-08-10 |
Other |
pipe in ceiling for LVO |
pipe in ceiling is leaking when the machine is running. Looks like a seal is weakening. |
|
|
Condensation |
|
2021-07-29 |
|
|
Sarah, Emily, and I all smelled gas coming from near the LVO. We powered the machine down and didn't use it for the remainder of the night, just to be extra safe. |
|
|
Complete |
|
2021-04-15 |
Plumbing |
|
the hose attached to the LVO has a crack in it. |
|
|
complete |
|
2021-04-08 |
|
|
The soap dispenser is clogged |
|
|
cleaned |
|
2021-03-24 |
|
|
Wash temp. is running low |
|
|
reset burner |
|
2021-03-13 |
Plumbing |
|
Soap clog on inside of LVO. Lee tried to spray it out without any luck. Mike aware. |
|
|
Complete |
|
2021-03-03 |
|
|
screw missing from handle on the inside of the LVO |
|
|
repaired |
|
2021-02-15 |
|
|
The rinse temp is running on the low side. It was holding during the first half of our shift but has since been dropping. |
|
|
explained low rinse temp to manager but it was on the hobart not LVO |
|
2021-02-06 |
|
|
Wash temp. running low |
|
|
Complete |
|
2021-01-13 |
|
|
LVO wash temp. was low and out of range. |
|
|
|
|
2021-01-03 |
Other |
fix hub on LVO |
LVO is making a strange noise during the wash cycle. Mike listened and said it's a hub. workin' |
|
|
Not sure that it is a hub or bearing issue because it is not making sound all the time. It could be a soap issue. I am working on it with the manufactorer |
|
2020-12-27 |
Other |
Adjust latch on LVO Door |
There is a gap on the door latch so when you turn the machine on the pressure pushes the door open and we're losing lots of water and it's creating lots of steam. |
|
|
adjusted |
|
2020-11-11 |
Other |
adding guard to metal cover |
Please add a guard to the metal piece that protects the motor from getting wet. One of our staff cut themselves on it. There is currently a piece of duct tape on the spot. |
|
|
taped edge |
|
2020-10-28 |
Plumbing |
|
LVO wash temp. was low and out of range most of the night. Should be at least 150 and was hovering around 100. |
|
|
see notes |
|
2020-10-13 |
|
|
Wash temp was running low |
|
|
reset burner |
|
2020-09-05 |
|
|
LVO at the end of the shift started making a loud unusual sound when turned on, so we stopped using it for the night. |
|
2:00:00 |
Complete |
|
2020-07-18 |
|
|
Hook on wall by LVO is loose. Screws need to be tightened. |
|
|
Complete |
|
2020-07-09 |
Other |
|
In order for the wash temperature to be the correct temp, we always have to make sure the burner is pressed 30 minutes before taking the temp. Is there a way that we can eliminate this step and not have to press the button so much, and with such a specific timing? |
|
|
only 1 reset today |
|
2020-06-24 |
Electrical |
|
The LVO wouldn't turn back on.
We took off the back panel and none of the panels were lit up.
We think that it might be the on/ off button isn't working? |
|
|
tripped breaker, blew fuse, replaced FLM 10 A |